The new LED ERP standard will be started from 1st. Sep,2013/// Functionality requirements for non-directional and directional LED lamps
TABLE 5
Functionality parameter
Requirement from Stage 1
Lamp Survival Factor at 6000h
≥0.90
Lumen Maintenance at 6000h
≥0.80
Number of switchig cycles before failure
≥ 15 000 if rated lamp life ≥ 30 000 h otherwise: ≥ half the rated lamp life expressed in hours
Starting time
<0.5s
Lamp warm-up time to 95%
<2s
Fremature Failure rate
≤5.0% at 1000h
Colour rendering(Ra)
≥80; ≥65 if the lamp is intended for outdoor or industrial applications according to paragraph(I) of Annex 3.1.2.
Colour consistency
Correlated Colour Temperature (CCT) spread within a 6-step MacAdam ellipse or less
Lamp power factor(PF)
P≤2W, no requirement;
2W<P≤5W: PF>0.4;
5W<P≤25W: PF>0.5;
P>25W: PF>0.9
If the lamp cap is a standardised type also used with filament lamps, then from Stage 2, the lamp shall be a much as possible compatible with equipment designed for installation between the mains and filament laps.